Altronix AL300ULPD4


AL300ULPD4 is a multi-output power supply/charger that converts a 115VAC/60Hz input into four (4) Class 2 Rated 12VDC or 24VDC power limited outputs.

Specifications:
Input:
  • Input 115VAC, 60Hz, 3.5A.
  • Input fuse rated @ 3.5A/250V.
Output:
  • 12VDC or 24VDC selectable output.
  • Burglar Alarm Applications (UL 603):
  • 12VDC = 10VDC-13.2VDC.
  • 24VDC = 20VDC-26.4VDC.
  • 12VDC or 24VDC @ 2.5A supply current.
  • Four (4) Class 2 Rated fuse protected power limited outputs.
  • Outputs are rated @ 3.5A.
  • Filtered and electronically regulated outputs.
  • Short circuit and thermal overload protection.
Battery Backup:
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
Supervision:
  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form "C" contacts).
  • Battery presence supervision (form "C" contacts).
Visual Indicators:
  • AC input, DC output and Battery LED indicators.
Temperature:
  • Operating 0° C to 49° C (32° F to 120° F).
  • Storage - 20° C to 70°C ( - 4° F to 158° F).
  • Relative Humidity 85% +/- 5%.
BTU/Hr (approx.):
  • 12VDC: 15 BTU/Hr.
  • 24VDC: 31 BTU/Hr.

Product Documents

Product Data Sheet

AL300ULPD4-DataSheet.pdf


This product is typically included with the following Kits (and items)

Majoris Access Add-On Kit
info



ALTRNX

12/24VDC 2.5A 4FSD OUT

AL300ULPD4

12/24VDC 2.5A 4FSD OUT


You are currently shopping as a GUEST.

Login



Login





Previous Page

Product Info Long

Altronix AL300ULPD4


AL300ULPD4 is a multi-output power supply/charger that converts a 115VAC/60Hz input into four (4) Class 2 Rated 12VDC or 24VDC power limited outputs.

Specifications:
Input:
  • Input 115VAC, 60Hz, 3.5A.
  • Input fuse rated @ 3.5A/250V.
Output:
  • 12VDC or 24VDC selectable output.
  • Burglar Alarm Applications (UL 603):
  • 12VDC = 10VDC-13.2VDC.
  • 24VDC = 20VDC-26.4VDC.
  • 12VDC or 24VDC @ 2.5A supply current.
  • Four (4) Class 2 Rated fuse protected power limited outputs.
  • Outputs are rated @ 3.5A.
  • Filtered and electronically regulated outputs.
  • Short circuit and thermal overload protection.
Battery Backup:
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
Supervision:
  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form "C" contacts).
  • Battery presence supervision (form "C" contacts).
Visual Indicators:
  • AC input, DC output and Battery LED indicators.
Temperature:
  • Operating 0° C to 49° C (32° F to 120° F).
  • Storage - 20° C to 70°C ( - 4° F to 158° F).
  • Relative Humidity 85% +/- 5%.
BTU/Hr (approx.):
  • 12VDC: 15 BTU/Hr.
  • 24VDC: 31 BTU/Hr.

Product Documents